• USB 2.0 Communication Link • 24 bits internal resolution • Up to 19 bits (±260,000 counts) noise free resolution • Up to 15,000 sample per second selectable rate • High accuracy (±0.005%) • Low non-linearity (±0.005%) • USB Output • Precision 4.6 VDC Excitation • Output for encoder purpose • Speed/Angle/Power Measurement • CE approval and RoHS compliant
• USB 2.0 Communication Link • 24 bits internal resolution • Up to 19 bits (±260,000 counts) noise free resolution • 5 to 4800 sample per second selectable rate • High accuracy (±0.001%) • Low non-linearity (±0.001%) • USB Output • Precision 4.6VDC Excitation • Output for encoder purpose • Speed/Angle/Power Measurement • CE approval and RoHS compliant
• USB 2.0 Communication Link • Sampling Rate: Up to 200 Samples Per Second • Up to ±50,000 count (noise-free) • None amplified input (selectable up to ±500 mV/V) • Speed measurement (Up to 150,000 Pulse per second) • Angle measurement • Up to 16 Point Stored Calibration • ASCII stream output • High resolution, high accuracy and low non-linearity • CE approval and RoHS compliant
• USB 2.0 Communication Link • Sampling Rate: up to 4800 Samples Per Second • Up to ±50,000 count (noise-free) • Amplified (Current Or Voltage) input (selectable up to ±10V or 0-20 mA) • Up to 16 Point Stored Calibration • ASCII stream output • High resolution, high accuracy and low non-linearity • CE approval and RoHS compliant
• USB 2.0 Communication Link • Sampling Rate: up to 4800 Samples Per Second • Up to ±300,000 count (noise-free) • mV/V input (selectable up to ±400 mV/V) • Up to 16 Point Stored Calibration • ASCII stream output • High resolution, high accuracy, and low non-linearity • CE approval and RoHS compliant
• Bipolar Output, Differential Input • ±5 or ±10 VDC Outputs • Selectable 1 KHz,10 KHz, 25 KHz Bandwidth • Bridge Excitation: 5 or 10 VDC (DIP Switch) • Ranges: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 4.0, 10.0 mV/V (DIP Switch) • Internal Span and Offset Potentiometers • Sensor Polarity Reversal DIP Switch • Zero Shift DIP Switch • CE approval and RoHS compliant
• Bidirectional Output, Differential Input • 4-20 mA Output • Selectable 1 KHz,10 KHz, 25 KHz Bandwidth • Bridge Excitation: 5 or 10 VDC (DIP Switch) • Ranges: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 4.0, 10.0 mV/V (DIP Switch) • Internal Span and Offset Potentiometers • Sensor Polarity Reversal DIP Switch • Zero Shift DIP Switch
• Bidirectional Output, Differential Input • Ultra low noise output • Up to 50 kHz bandwidth • 4-20 mA Output • Bridge Excitation: 5 or 10 VDC (DIP Switch) • Ranges: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 4.0, 10.0 mV/V (DIP Switch) • 256 Selectable Shunt Combinations • Externally Accessible Shunt Cal Activation Button • Internal Span and Offset Potentiometers • Sensor Polarity Reversal DIP Switch • Zero Shift DIP Switch • CE approval and RoHS compliant
• 1-channel analogue input temperature Pt100 / thermocouple • Temperature measurement at 16 bit resolution • Pt100 and thermo signals type J, K and L • Wire break and short circuit detection • Protocol: CANopen CiA 404 • Expanded ambient temperature range of -40°C .. +85°C • Mechanic shock resistance of up to 40 G (optional) • Vibrations resistance of 3 .. 800 Hz @ 4.5 Grms (optional)
• Mantracourt LCD20 • Intelligent, compact, stackable microprocessor for smarter automation and process control • Fully isolated standard analogue outputs 4-20mA and 0-10V • Full digital setup & easy programming via handheld unit or USB connection to a PC using intuitive toolkit • software. • Increase reliability with 2 single pole relays & digital inputs • 10 point linearization, providing superior accuracy • 6 wire load cell connection to compensate for barrier and cable losses • Lockable features prevents loss of device settings through user misuse • Configuration can be save and restored for security of setup
Model:LCV-USB2 • Lorenz Messtechnik LCV-USB2 • Supply of the Measuring System via PC USB Port • Fast Measurement of up to 5000 Measurements/s Up to 16 bit Resolution • Input Ranges for mV, V and mA • Integrable in large Sensors as Board • Adjustment and Control Signal Switch via Software • High Level of Protection IP67
Model:SI • Analog • Lorenz Messtechnik SI • High Accuracy • Voltage or Current Output • Direct Connection to PLC • Long Input Lead from SI to Evalua- tion possible • Applicable in heavy Industries by robust Aluminum Casting Housing • High Level of Protection IP66
Model:LCV • Lorez Messtechnik LCV • High Accuracy • Direct Connection to PLC • Long Input Lead Possibility from LCV to Evaluation • Voltage or Current Output • Integrable in large Sensors as Board • High Level of Protection IP67
Model:IHH500 Pro • Futek FSH03571 • 24 bits internal resolution • Up to 20 bits (±500,000 counts) noise free resolution • 5 to 4800 sample per second selectable rate • High accuracy (±0.001%) • Low non-linearity (±0.001%) • Input range up to ±500mV/V (Strain Gauge) • Input range ±12VDC (Amplified Input) • Input range up to 30 mA (Amplified Input) • Minimum bridge resistance: 30 ohm • Encoder TTL (Elite Version) • USB Output • ASCII stream output • CE approval and RoHS compliant • Precision 5.000V Excitation • 24V/5V Output • Analog Voltage and Current Output
Model:IHH500 Elite • Futek FSH03460 • 24 bits internal resolution • Up to 20 bits (±500,000 counts) noise free resolution • 5 to 4800 sample per second selectable rate • High accuracy (±0.001%) • Low non-linearity (±0.001%) • Input range up to ±500mV/V (Strain Gauge) • Input range ±12VDC (Amplified Input) • Input range up to 30 mA (Amplified Input) • Minimum bridge resistance: 30 ohm • Encoder TTL (Elite Version) • USB Output • ASCII stream output • CE approval and RoHS compliant • Precision 5.000V Excitation • 24V/5V Output • Analog Voltage and Current Output
Model:PSD • Mantracourt PSD • Handheld 7 digit LCD display with peak, trough, net, overload and shunt cal indication • Battery life of 450 hours in power save mode • Keys for on/off, range select, peak/valley hold, and gross/net • Single pass calibration (direct mV/V) with dual range for values such as kg and lb • Easy to carry - weighing only 250 grams • Waterproof IP65 NEMA4 battery powered • Microprocessor based, allowing single pass calibration facility (direct mV/V) • TEDS enabled for automatic sensor calibration (IEEE1451 - template 33)
Model:GM77 • Lorenz-messtechnik GM77 • Display and Decimal Point Freely Scalable • Mains-, Battery-, Accu Operation • Cut-Off after 15 min • Calibration Control Switch • Maximum Value Memory • Signal Conversion Switch • Integrated Accu Charger • 41⁄2-digit LCD-Display • Easiest Calibration
Model:XN4 • Texense XN4 • High temp amplifier • Programmable Gain and Offset • Offset value from 0 to 5V • Working temperature from -20 to +125°C • Supply voltage: 5 to 16 V • Supply current (amp only): < 5 mA • Noise reduction • Output signal: 0 - 5 V • Dimensions: 13x10x4 mm