• 1 input channel supporting Thermocouples, Resistance Thermometers and Thermistors
• On-board linearization algorithms supporting a wide range of temperature transducers
• Up to 128 Hz sampling
• High resolution 24-bit data
• Digital filtering for up to 120 db rejection of 50 and 60 Hz noise
• Wireless range up to 1km (400 m)
• Supply power from 3.3 to 30 V
• Continuous, periodic burst, and event-triggered sampling
• LXRS protocol allows lossless data collection, scalable networks and node synchronization of ±50 µs
The TC-Link®-200-OEM allows users to collect data from a range of sensor types including Thermocouples, Resistance Thermometers, and Thermistors. The node supports high resolution, low noise data collection from 1 temperature transducer at sample rates up to 128 Hz. Users can easily program nodes for continuous, periodic burst, or event-triggered sampling with the SensorConnect software. The optional web-based SensorCloud® interface optimizes data aggregation, analysis, presentation, and alerts for sensor data from remote networks.
General |
|
---|---|
Sensor input channels |
Thermocouple, RTD, or Thermistor input, 1 channel |
Integrated sensors |
Temperature CJC, 1 channel |
Digital filter | Adjustable low pass filter with 3db frequency as low as 2.3 Hz and up to 120 db 50/60 Hz rejection |
Thermocouple Input |
|
Measurement range | -210° C to 1820° C (depending on thermocouple type) |
Accuracy | ±0.5° C (20 to 70° C node temperature) ±1° C (-40 to 85° C node temperature) |
Resolution | 0.1° C |
Compatible types | J, K, N, R, S, T, E and B |
RTD Input |
|
Measurement range | -200° C to 850° C |
Accuracy | ±0.5° C (depending on RTD accuracy) |
Resolution | 0.01 ° C |
Compatible types | PT-10, PT-50, PT-100, PT-200, PT-500, PT-1000 |
Thermistor Input |
|
Measurement range | -40° C to 150 °C (depending on Thermistor type) |
Accuracy | ±0.2° C (depending on Thermistor accuracy) |
Resolution | 0.02° C |
Compatible types | 44004, 44033, 44005, 44030, 44006, 44031, 44007, 44034, 44008, 44032, YSI-400 |
Integrated Temperature Cold Junction Compensation (CJC) Channel |
|
Compensation range | -40 °C to 85 °C (0 °C to 85 °C for type B Thermocouples) |
Accuracy | ±0.13 °C (20 °C to 70 °C), ±0.25 °C (-40 °C to 85 °C) |
Resolution | 0.02 °C |
Sampling |
|
Sampling modes | Continuous, periodic burst, event triggered |
Output options | Temperature, mV, Resistance or custom |
Sampling rates | 1 channel: up to 128 Hz |
Sample rate stability | ±5 ppm |
Network capacity | Up to 128 nodes per RF channel (bandwidth calculator:)www.microstrain.com/configure-your-system |
Node synchronization | ±50 µsec |
Data storage capacity | 16 M Bytes (up to 8,000,000 data points) |
Operating Parameters |
|
Wireless communication range | Outdoor/line-of-sight: 2 km (ideal), 800 m (typical)Onboard antenna: 1 km (ideal), 400 (typical) Indoor/obstructions: 50 m (typical) |
Radio frequency (RF) transceiver carrier |
License-free 2.405 to 2.480 GHz (16 channels) |
RF transmit power | User-set 0 dBm to 20 dBm. restricted regionally |
Operating temperature | -40 °C to +105 °C |
ESD | 4 kV |
Physical Specifications |
|
Dimensions | 41.3 mm x 29 mm x 5.9 mm |
Interface | Solder or screw-down terminal available |
Weight | 7 grams |
Integration |
|
Compatible gateways | All WSDA gateways |
Software | SensorCloud®, SensorConnect, Windows 7, 8 & 10 compatible |
Software development kit | http://www.microstrain.com/software/mscl |
Regulatory compliance | FCC (USA), IC (Canada), CE (European Union), JET (Japan) |